Distribution Network Power System (Fault Diagnosis)

Introduction

Distribution systems are prone to fault occurrences due to various reasons, such as lightning strikes, human error and failure of components. These phenomena affect the customers’ access to power and require repairs to be done to restore their supply.

This module covers the diagnosis of fault occurrences and the restoration of supply. Through theoretical, practical ,and simulation training, participants will leave the 3 day course with the knowledge and the skills needed to perform fault diagnosis.

ELECTRICAL ENGINEERS, TECHNICAL EXECUTIVES, COMPETENT ENGINEERS, SUPERVISING ENGINEERS, TECHNICAL MANAGERS, ELECTRICAL TECHNICIANS, ELECTRICAL CHARGEMAN

Target Participant

ILSAS BANGI

Venue

3 DAYS

Duration

Objective

At the end of the course, participants will be:

  • Knowledgeable on the protective system, protective scheme and protective equipment in a 33kV Distribution Network
  • Able to diagnose different types of faults in the 33kV Distribution Network
  • Recognise the function, type, device code and numbering of protection relays in the Main Distribution Substation
  • Remember the TNBD Work Instruction & Circulars related to post breakdown, isolation of faulted circuit and restoration of supply

Agenda

Day 1

Application of Distribution Network Protection

  • Common 33kV Feeder protection scheme and relays used
  • Common 33/11kV power transformer protection scheme and relays
  • Main & Back-up protection for Feeder and Transformers
  • Unit & Non-Unit protection
  • Voltage & Current balanced scheme
  • The behaviour of Feeder Unit protection if fed from one end or both ends
  • The necessity for Back-up Protection
  • Auto Re-closer scheme with shots and lockout
  • Inter trip scheme
  • Trip circuit supervision

Given Single Line Diagram of 33kV Simulator

  • Trainees fill up the type, device code & numbering of relays used for each Feeder and Transformer protection
Day 2

Fault Diagnosis

  • Trainees are divided into groups and given fault scenarios at the simulator
  • Practical session on tripping, fault diagnosis, reporting, isolation and restoration of supply
Day 3

Presentation, Diagnosis & Discussion

  • Analysis of the tripping, fault diagnosis, reporting, isolation of faulted circuit and restoration of supply as per Energy Commission Malaysia and TNBD Certification system which includes Job Sheet, Sanction, Authorization and Permit-to-Work forms.

What people say?

It was a perfect match seeing that i need to work on my confidence.I actually learnt more skills that is needed for me to be able to develop training programs.
Bodil Dahl
Ceo & Founder Crix
The course definitely helped in improving concepts. It would be great if you add more examples of templates for Training evaluation. This would help in creating better sheets in future. Thanks
Sonal Tyagi
Head Of Sales , Intel

Acknowledgement

Summary of Personal Data Protection Notice

This summary notice provides the key concepts of the Personal Data Protection Notice which applicable at Tenaga Nasional Berhad and our subsidiaries, which is available at our website.

Personal Data We May Collect & How We Collect It

We may collect your personal data including sensitive personal data such as personal information directly from you, your authorized representatives, third parties or from publicly resources. If you are a job applicant, employee or work for us, we shall provide a separate Notice to inform you how your personal data is used via our applicable platform.

Use of Personal Data Collected

We use your personal data to enable us to provide our services and matters related to it, send information on our services, for the purpose of audit and to comply with the regulatory obligations or industry codes.

With Whom We Share Your Personal Data

We disclose your personal data to the third parties located within or outside Malaysia who work on our behalf or help to provide our services.

If Personal Data Provided by You Is Incomplete

We may not be able provide you with our services for if the personal data given is incomplete.

Your Rights to Your Personal Data

You may request to access,correct and portability of your personal data held by us.

How Long We Will Keep Your Personal Data & How We Protect It

Your personal data will be retained to fulfil the purpose for which it is collected or to comply with legislation and internal requirements in which we will keep it safe.

Consent

By submitting your personal data, you consented to the processing of personal data as set out in this Notice.

Our Contact Details

TNB or its subsidiaries is committed to protecting your personal data. If you have questions or comments about TNB’s administration of personal data relating to electricity supply, please contact us at tnbcareline@tnb.com.my or 1-300-88-5454.

If you have any questions, comments or suggestions regarding this Policy, we would be glad to hear from you. Please contact our TNB Data Protection Officer at dpo@tnb.com.my

For more information, please download our full PDPA Notice here: