RM 3.6K
132kV Transmission Protection Competency Training Part 2 (Theory)

132kV Transmission Protection Competency Training Part 2 (Theory)
Transmission

Overview:
132 KV Transmission Protection Competency Training Part  (Theory) is referring to the protection scheme itself such as line protection, busbar protection, ICT Interface and application of testing equipment. In this course, the participant can share experience on settings, testing & commissioning, troubleshooting fault case studies, fault investigation and engineering analysis.

Objective:
After attending this course the participants shall be able to:

• Describe the operating principle of the distance protection function & schemes
• Describe the Line Protection Scheme
• Describe the application criteria & operating mode of Autoreclose & Synchronising Check relay
• Explain how the Operating and communication principle of a Current Differential Protection system
• Explain the Operating principle of a Pilot Wire Protection System
• Describe the working principle of busbar protection in TNB installation
• Describe the teleprotection channel in Transmission system
• Explain the proper approach and method to test protection relays and scheme

Duration: 4 Days


Request Form





Available Sessions

Upon Request


Other Information
Target Participant: Non Competent Protection


Price

Upon Request



Related Course

RM 3.6K
Lines And Underground Cable Design And Maintenance / Rekabentuk Dan Senggaraan Talian Dan Kabel Bawah Tanah
Transmission

3 Days

View Details

Overview:
132 KV Transmission Protection Competency Training Part  (Theory) is referring to the protection scheme itself such as line protection, busbar protection, ICT Interface and application of testing equipment. In this course, the participant can share experience on settings, testing & commissioning, troubleshooting fault case studies, fault investigation and engineering analysis.
Objective:
After attending this course the participants shall be able to:

• Describe the operating principle of the distance protection function & schemes
• Describe the Line Protection Scheme
• Describe the application criteria & operating mode of Autoreclose & Synchronising Check relay
• Explain how the Operating and communication principle of a Current Differential Protection system
• Explain the Operating principle of a Pilot Wire Protection System
• Describe the working principle of busbar protection in TNB installation
• Describe the teleprotection channel in Transmission system
• Explain the proper approach and method to test protection relays and scheme

Target Participant: Non Competent Protection
Duration: 4 Days
Language:

RM 3.6K
132/275kV LiveLine Training - Competency
Transmission

39 Days

View Details

Overview:
132 KV Transmission Protection Competency Training Part  (Theory) is referring to the protection scheme itself such as line protection, busbar protection, ICT Interface and application of testing equipment. In this course, the participant can share experience on settings, testing & commissioning, troubleshooting fault case studies, fault investigation and engineering analysis.
Objective:
After attending this course the participants shall be able to:

• Describe the operating principle of the distance protection function & schemes
• Describe the Line Protection Scheme
• Describe the application criteria & operating mode of Autoreclose & Synchronising Check relay
• Explain how the Operating and communication principle of a Current Differential Protection system
• Explain the Operating principle of a Pilot Wire Protection System
• Describe the working principle of busbar protection in TNB installation
• Describe the teleprotection channel in Transmission system
• Explain the proper approach and method to test protection relays and scheme

Target Participant: Non Competent Protection
Duration: 4 Days
Language:

RM 3.6K
Electrical Regulation Act
Transmission

4 Days

View Details

Overview:
132 KV Transmission Protection Competency Training Part  (Theory) is referring to the protection scheme itself such as line protection, busbar protection, ICT Interface and application of testing equipment. In this course, the participant can share experience on settings, testing & commissioning, troubleshooting fault case studies, fault investigation and engineering analysis.
Objective:
After attending this course the participants shall be able to:

• Describe the operating principle of the distance protection function & schemes
• Describe the Line Protection Scheme
• Describe the application criteria & operating mode of Autoreclose & Synchronising Check relay
• Explain how the Operating and communication principle of a Current Differential Protection system
• Explain the Operating principle of a Pilot Wire Protection System
• Describe the working principle of busbar protection in TNB installation
• Describe the teleprotection channel in Transmission system
• Explain the proper approach and method to test protection relays and scheme

Target Participant: Non Competent Protection
Duration: 4 Days
Language:

Human Resource Minister - Training Provider Award 2007
Role Model Company 2013 for Electrical Training Programmes by Manpower Department (JTM)
Energy Industry Award: Training Institution Excellence 2011

TNB Integrated Learning Solution Sdn Bhd - ILSAS
Jalan IKRAM-UNITEN, Karung Berkunci 205,
43650 Bandar Baru Bangi, Selangor, MALAYSIA

T: (+6) 03-8922 7222 F: (+6) 03-8926 4437 E: infoilsas@tnb.com.my

© 2017 TNB ILSAS