RM 3.6K
KENDALIAN PENCAWANG 33kV Modul 2 – Kendalian Sistem        SUBSTATION OPERATION 33kV Module 2 – System Operation

KENDALIAN PENCAWANG 33kV Modul 2 – Kendalian Sistem SUBSTATION OPERATION 33kV Module 2 – System Operation
Distribution

Overview:
Emphasis of this 5 days module is live 33kV switching for planned outages. Theory lessons include procedure writing i.e. given a certain task, the correct switching procedure and sequence must be written in accordance to requirement of Energy Commission Malaysia and TNBD Safety Rules.
The practical lesson is where the actual task is carried out. All safety aspects must be adhered to in performing the task i.e. the use of personnel protective equipment, proof testing of high voltage measuring equipment before and after usage, non-standard lock, caution & danger notices, locking & tagging techniques, rubber mats, testing for zero voltage prior to engaging Circuit Main Earth, communication between Controller and Authorised/Competent Person and issuance of written instruction to carry out work safely.

Objective:
*         Operate 33kV Air & Gas Insulated switchgears
*         State & explain the need for locking & tagging with relevant notices
*         Write switching operation procedures & sequence for planned outages of 33kV distribution system as required by Energy Commission Malaysia, TNBD Safety Rules, TNBD Circulars & Work Instructions
*         State & explain the use of high voltage indicator and phase comparison equipment.
*         Perform live 33kV switching operation in accordance to rules by Energy Commission Malaysia & TNBD Safety Rules.
*         State and explain the certification system in high voltage switching

Duration: 5


Request Form





Available Sessions

Upon Request


Other Information
Target Participant: o ELECTRICAL ENGINEERS o TECHNICAL EXECUTIVES o COMPETENT ENGINEERS o SUPERVISING ENGINEERS o TECHNICAL MANAGERS o ELECTRICAL TECHNICIANS o ELECTRICAL CHARGEMAN
Languages: English, Malay


Price

RM RM4500



Related Course

RM 3.6K
Distribution Technical Drawing Using AutoCAD (for Non-exec)
Distribution

3

View Details

Overview:
Emphasis of this 5 days module is live 33kV switching for planned outages. Theory lessons include procedure writing i.e. given a certain task, the correct switching procedure and sequence must be written in accordance to requirement of Energy Commission Malaysia and TNBD Safety Rules.
The practical lesson is where the actual task is carried out. All safety aspects must be adhered to in performing the task i.e. the use of personnel protective equipment, proof testing of high voltage measuring equipment before and after usage, non-standard lock, caution & danger notices, locking & tagging techniques, rubber mats, testing for zero voltage prior to engaging Circuit Main Earth, communication between Controller and Authorised/Competent Person and issuance of written instruction to carry out work safely.
Objective:
*         Operate 33kV Air & Gas Insulated switchgears
*         State & explain the need for locking & tagging with relevant notices
*         Write switching operation procedures & sequence for planned outages of 33kV distribution system as required by Energy Commission Malaysia, TNBD Safety Rules, TNBD Circulars & Work Instructions
*         State & explain the use of high voltage indicator and phase comparison equipment.
*         Perform live 33kV switching operation in accordance to rules by Energy Commission Malaysia & TNBD Safety Rules.
*         State and explain the certification system in high voltage switching

Target Participant: o ELECTRICAL ENGINEERS o TECHNICAL EXECUTIVES o COMPETENT ENGINEERS o SUPERVISING ENGINEERS o TECHNICAL MANAGERS o ELECTRICAL TECHNICIANS o ELECTRICAL CHARGEMAN
Duration: 5
Language: English, Malay

RM 3.6K
CABLE LAYING AND JOINTING UP TO 33KV
Distribution

3

View Details

Overview:
Emphasis of this 5 days module is live 33kV switching for planned outages. Theory lessons include procedure writing i.e. given a certain task, the correct switching procedure and sequence must be written in accordance to requirement of Energy Commission Malaysia and TNBD Safety Rules.
The practical lesson is where the actual task is carried out. All safety aspects must be adhered to in performing the task i.e. the use of personnel protective equipment, proof testing of high voltage measuring equipment before and after usage, non-standard lock, caution & danger notices, locking & tagging techniques, rubber mats, testing for zero voltage prior to engaging Circuit Main Earth, communication between Controller and Authorised/Competent Person and issuance of written instruction to carry out work safely.
Objective:
*         Operate 33kV Air & Gas Insulated switchgears
*         State & explain the need for locking & tagging with relevant notices
*         Write switching operation procedures & sequence for planned outages of 33kV distribution system as required by Energy Commission Malaysia, TNBD Safety Rules, TNBD Circulars & Work Instructions
*         State & explain the use of high voltage indicator and phase comparison equipment.
*         Perform live 33kV switching operation in accordance to rules by Energy Commission Malaysia & TNBD Safety Rules.
*         State and explain the certification system in high voltage switching

Target Participant: o ELECTRICAL ENGINEERS o TECHNICAL EXECUTIVES o COMPETENT ENGINEERS o SUPERVISING ENGINEERS o TECHNICAL MANAGERS o ELECTRICAL TECHNICIANS o ELECTRICAL CHARGEMAN
Duration: 5
Language: English, Malay

RM 3.6K
MASTER STATION - MODULE 2 (EXEC & NON-EXEC)
Distribution

4

View Details

Overview:
Emphasis of this 5 days module is live 33kV switching for planned outages. Theory lessons include procedure writing i.e. given a certain task, the correct switching procedure and sequence must be written in accordance to requirement of Energy Commission Malaysia and TNBD Safety Rules.
The practical lesson is where the actual task is carried out. All safety aspects must be adhered to in performing the task i.e. the use of personnel protective equipment, proof testing of high voltage measuring equipment before and after usage, non-standard lock, caution & danger notices, locking & tagging techniques, rubber mats, testing for zero voltage prior to engaging Circuit Main Earth, communication between Controller and Authorised/Competent Person and issuance of written instruction to carry out work safely.
Objective:
*         Operate 33kV Air & Gas Insulated switchgears
*         State & explain the need for locking & tagging with relevant notices
*         Write switching operation procedures & sequence for planned outages of 33kV distribution system as required by Energy Commission Malaysia, TNBD Safety Rules, TNBD Circulars & Work Instructions
*         State & explain the use of high voltage indicator and phase comparison equipment.
*         Perform live 33kV switching operation in accordance to rules by Energy Commission Malaysia & TNBD Safety Rules.
*         State and explain the certification system in high voltage switching

Target Participant: o ELECTRICAL ENGINEERS o TECHNICAL EXECUTIVES o COMPETENT ENGINEERS o SUPERVISING ENGINEERS o TECHNICAL MANAGERS o ELECTRICAL TECHNICIANS o ELECTRICAL CHARGEMAN
Duration: 5
Language: English, Malay

Human Resource Minister - Training Provider Award 2007
Role Model Company 2013 for Electrical Training Programmes by Manpower Department (JTM)
Energy Industry Award: Training Institution Excellence 2011

TNB Integrated Learning Solution Sdn Bhd - ILSAS
Jalan IKRAM-UNITEN, Karung Berkunci 205,
43650 Bandar Baru Bangi, Selangor, MALAYSIA

T: (+6) 03-8922 7222 F: (+6) 03-8926 4437 E: infoilsas@tnb.com.my

© 2017 TNB ILSAS